Core Principle: Regular maintenance is key to ensuring performance and extending the fixture’s lifespan.
I. Daily Maintenance (After Each Use)
- Cool Before Storage: Allow the fans to completely stop after power off before disconnecting power. Never hot-plug.
- Clean Filters: Use a soft brush or vacuum cleaner to remove dust from the heat dissipation filters. If washed, ensure they are thoroughly dry before reinstalling.
- Check Cables: Inspect power and DMX cables for damage and ensure connectors are intact.
II. Regular Maintenance (Monthly or Every 50 Hours)
- Internal Dusting: Power down, open covers, and use compressed air or a soft brush to gently remove dust from PCBs, fans, and optical components.
- Lubricate Drive System: Check X/Y axis belts and gears. Use only specialized lubricant.
- Full Function Test: Run the self-test program to check movement, color, gobos, dimming, and other functions.
III. Deep Maintenance (Quarterly or Every 200-500 Hours)
- Professional Calibration: Have a technician calibrate the optical path to ensure beam accuracy.
- Lamp Replacement: Wear gloves. Never touch the new lamp’s glass bulb directly with bare hands. Reset lamp hours after replacement.
Important Safety Notes:
- All operations must be performed with the power completely disconnected.
- Handle with care to avoid severe shocks and vibrations.
- When maintaining optical components, use professional tools to avoid scratches.
Common Issues Quick Check:
- No Power: Check power cable and fuse.
- No Light: Lamp life expired or trigger fault.
- Communication Failure: Check DMX cable, address setting, and terminator.
- Movement Noise: Needs lubrication or check belts/gears.
We are Joyfirst Lighting. Explore and choose our high-quality beam moving head lights: Bulb Beam Moving Head Lights – Joyfirst Lighting